direkt zum Inhalt. direkt zum Hauptmenü.

Container applications

Container applications

Base frame

Welded steel construction and rolling hollow profiles
Upper container reinforced corners
Corrosion proof
All steel parts are rust-proof treated and primed, galvanizing on request

Floor structure

Floor cross elements with pickled false bottom made of galvanized sheet metal
Insulation with mineral wool
Polyethylene film as a vapor barrier
Chipboard plate 19 - 22 mm V100 E1, or cement-bonded plate bolted to longitudinal selection steel beam
Traffic load 2.500 N/m, higher traffic load on request

Surface

PVC coverings, carpets

Siding

Galvanized profile sheet

Wall construction

Profile frame, reinforced with internal woods
Insulated with mineral wool, fire protection class A2 according to DIN 4102
Polyethylene film, 0,05 mm, as a vapor barrier

Isolation

Bottom: 120 mm mineral wool, K = 0,33 W/mK
Walls:   100 mm mineral wool, K = 3,35 W/m K 
Ceiling: 200 mm mineral wool, K = 0,21 W/m K

Exterior Paint

Two-component paint, leaf-free, RAL...(according to desire)

Roof

Roofing made of galvanized sheet metal profiles, vented, bolted together at the end faces
Supported on profile steel beams
Gutter with 4 downspouts, ID 50, insulated with mineral wool, fire protection class A2 according to DIN 4102
Polyethylene film, 0,05 mm, as a vapor barrier
Roof load 1.500 N/m, higher traffic load on request

Internal trim

Ceiling:
Plastic coated chipboard, 10 mm, white, riveted to steel chassis, mineral fiber ceiling in fire protection call A1 or A2
 
Walls:
Plastic coated chipboard, 13 mm, white or wood finish
 
Separation walls:
Frame construction, suitable for interior wall cladding, mineral wool, 40 mm, inside

Doors

Exterior:
Galvanized steel door, 87,5/200 cm, isolated Circumferential rubber seal
Profile cylinder lock with long handle and shield set, 3 keys
Plastic coated
 
Inside:
Lacquered steel door, 80/197 cm, plastic coated, white or with finished wood decor Warded lock with a long handle and shield set, 1 key

Windows

Plastic window with swivel-/rotating fitting, circumferential seal
double glass isolation windows, K = 1,3 or 1,1 W/mK
plastic shutters

Electrical installation

VDE 0100
Distribution main, secondary distribution, fuse board with RCD and sufficient number of outlets
Linear luminaires, socket outlets, single switch, series or changeover switch, button
Complete concealed wiring

Heating

Electric convectors